INFINITE CONTROLS
The infinite control switch gives infinite control for non-inductive loads up to 15 Amps on 120 or 240 V-AC (cannot be used with an external contactor). It can be turned either to left or right to adjust proper heat from 0-100% wattage with infinite control over the first 50% of total wattage.  Energized continuously in HI position, at other settings it delivers selected input level under control of a simple bimetal timer.  Only 3 mounting holes are necessary to install the INFINITE CONTROL SWITCH in customer supplied box or panel. It is designed for use at ambient temperatures up to 85°C.
 
   
FUNCTIONAL DESCRIPTION
 
 

The model INF turns clockwise or counterclockwise.. A double-line disconnect is provided when the control is in the "Off" position. The permanent magnet provides snap action of contacts. Clean makes and breaks ensure long life of the fine silver contacts. The switch control is ambient compensated. It is designed for operation where ambient temperature does not exceed 85°C. The control contains a bimetal, which regulates the running cycles. This bimetal has a resistance wire wrapped around it,

which is connected in parallel with the heating unit being controlled and cycles in unison with the heating element. When the switch is turned to "ON" position, the follower moves out and allows the contacts to close. This completes a circuit through a heating unit being controlled, and also to the resistance wire wrapped around the bimetal. At this time the steel armature is under the influence of the magnetic pull of magnet. As the resistance wire heats the bimetal, the bimetal flexes and forces are built up in it. When the force built up is equal to the magnetic pull of the magnet, the contacts open with a snap action and the steel armature will be pulled away from the magnetic field. This opens the contacts, which will cut off the power of the heating unit being controlled and will also disconnect the power to the bimetal-Resistance wire. As the bimetal cools, it will then flex in the opposite direction and the contacts will start moving closer together. At a certain point the magnetic pull will close with a snap action. This then will permit current to flow throughout the unit once again as the circuit is complete. A second bimetal is employed as an ambient temperature compensator to neutralize the effect of the surrounding temperatures on the control bimetal. These controls are designed to operate in locations where the maximum ambient temperature does not exceed approximately 85°C. The infinite control switch can control any resistive load up to 15 amps.

It is possible to obtain a range of inputs to the element and/or load from approximately 5% at low- 100% at high, and infinite settings in between.
 
TECHNICAL SPECIFICATIONS
   
LINE INPUT : 230V OR 120V + 20%,15Amp MAX  
RANGE : 5% at low- 100% at high, adjustable  
ISOLATION : 2.5kv A.C, for 1 minute, leakage current <3.5mA  
LERAKAGE CURRENT : < 210 mA  
OPERATING TEMPERATURE : 0 to 85°C  
LIFE : 1,00,000 Switching cycles under normal conditions  
SAFETY : Meets VDE, IEC Standards  
EMC : CE MARKED  
DIMENSIONS : LENGTH-40MM WIDTH-40MM HEIGHT-74MM APPROX.  
WEIGHT : 110gm APPROX. WITHOUT DIAL PLATE  
 

FEATURES

 
       
  Simplicity of design with no cams or levers to adjust, and no motor to burn out
  Automatic compensation for line voltage fluctuations up to ± 15%  
  Bimetal acts at settings less than HI to limit electrical input and depress temperature
 
  Mechanical Bi-Metal Operation  
  Knob Setting 0 - 100% Output  
  Double Pole, Single Throw  
  (DPST) Snap-Action  
  Positive Break  
  120 or 240 V(Ac) depending on model  
  1,800 & 3,600 Watts  
  Cannot be used with a contactor  
   
 

INSTALLATION INSTRUCTIONS:

 
 
L1 and L2 represent line connections at the incoming source.
H1 and H2 equal load connections that are connected to the load."P" is for pilot light attachment
Maximum Thread Torque 12 in/lbs for palnut mounting.
 

APPLICATION

 
   

Annealing, Melting Pots, Industrial cooking, Dies, Platens,Comfort heating, Electric furnaces, Molding, Industrial hot plates, Laboratory ovens

 
   
WARNING:  
   
Hazard of Fire. These devices function as energy controls only. Because they do not fail-safe, an approved temperature and/ or pressure safety control must be used for safe operation
 

Model

Volts

Max.Rating Watts,AC

BHA-159

120

1800

BHA-259

240

3600

 

Next 1 | 2 | 3 | 4
 
 
 
   OUR PRODUCTS


 

Energy regulators
 

Thermostat

 

Heating Element

 

Ceramics For Thermocoule & Heater

 

 

Brass spares for Heating & Thrmocouple Industry

 
 

Thermcouples

  Jewellary & soldering

 

 
 
   Contact us
PEENA TRADERS
158, VEENA DALVAI INDUSTRIAL ESTATE, S.V.ROAD, OSHIWARA, JOGESHWARI (W),
BOMBAY-400102, INDIA
TEL: +91-22-26794098  
FAX: +91-22-66780096
E-MAIL: peena@vsnl.com
URL: http://www.bhahk.com/
 
   
  Copyright 2006 Peena Traders. All right reserved Design, Developed, Hosted & mainted By Aakruti Creations